> Home > Architectural and Engineering Design Guidelines > Standard Design Detail Drawings > Standard Detail Drawings - 2300 Series - Water Information

Standard Detail Drawings - 2300 Series - Water Information

2300 Series - Water Information (pdf / 6.4MB / 42pgs)
(entire series in PDF format) 2008 Revision
Individual Drawings are provided in both PFD and DWG file formats.
DWG files require software such as AutoCAD or MicroStation to download.
2305-1 Butterfly Valve Operator Manhole PDF- 72KB DWG- 30KB
2305-2 Butterfly Valve Operator Manhole PDF- 60KB DWG- 38KB
2315 Nonpotable Water Valve Box & Cover PDF- 69KB DWG- 77KB
2330 Water Service Line Connection PDF- 143KB DWG- 55KB
2332 Chlorine Injection Tap PDF- 70KB DWG- 27KB
2333 Tap For Future Chlorine Injection PDF- 68KB DWG- 69KB
2342-1 Pressure Reducing Valve PDF- 171KB DWG- 255KB
2342-2 Pressure Reducing Valve PDF- 113KB DWG- 80KB
2345-1 3", 4", 6" Water Meter PDF- 123KB DWG- 227KB
2345-2 3", 4", 6" Water Meter PDF- 118KB DWG- 89KB
2346 Temporary Construction Meter PDF- 144KB DWG- 124KB
2348 Air / Vacuum Release Valve PDF- 221KB DWG- 536KB
2349 Water Quality Sampling Station PDF- 110KB DWG- 282KB
2351 Double Check Valve Backflow Prevention
Assembly For Assemblies 3" Thru10"
PDF- 216KB DWG- 159KB
2352 Double Check Valve Backflow Prevention
Assembly For Assemblies 3/4" Thru 2 1/2" 2008 Rev.
PDF- 158KB DWG- 79KB
2353 Reduced Pressure Principle Backflow Prevention
Assembly For Assemblies 3" Thru 10"
PDF- 217KB DWG- 204KB
2354 Reduced Pressure Principle Backflow Prevention
Assembly For Assemblies 3/4" Thru 2 1/2" 2008 Rev.
PDF- 157KB DWG- 82KB
2355 Pressure Vacuum Breaker Assembly For
Assemblies 1/2" Thru 2" 2008 Rev.
PDF- 148KB DWG- 67KB
2356 Guard Posts For Backflow Prevention Assemblies PDF- 80KB DWG- 105KB
2357 Fill Pipe Details For Portable Tanks w/ Air Gap Separation PDF- 79KB DWG- 57KB
2358 Backflow Prevention For Portable Tanks With No
Air Gap Separation
PDF- 84KB DWG- 68KB
2359 "N" Shaped Double Check Valve Backflow
Prevention Assembly For Assemblies 3" Thru 10"
PDF- 217KB DWG- 250KB
2360 "N" Shaped Reduced Pressure Principle Backflow
Prevention Assembly For Assemblies 3" Thru 10"
PDF- 220KB DWG- 228KB
2361 Fire Hydrant Bypass Assembly PDF - 70KB DWG -44KB
2362-1 1-1/2" - 2" Fire Line Connection  PDF- 140KB DWG- 57KB
2362-2 3" And Larger Fire Line Connection PDF- 140KB DWG- 57KB
2363 Pavement Markers For Fire Hydrants PDF- 131KB DWG- 59KB
2364 Fire And Emergency Access And Delineation PDF- 153KB DWG- 125KB
2365 Fire Lane Sign PDF- 140KB DWG- 52KB
2366 Concrete Collar for Fire Hydrants PDF- 86KB DWG- 73KB
2367

Fire Department Remote Siamese Connection 2008 Rev.

PDF- 120KB DWG- 92KB
2368

Fire Sprinkler Riser Detail - Vertical Installation #1 2008 Rev.

PDF- 146KB DWG- 127KB
2369

Fire Sprinkler Riser Detail - Vertical Installation #2 2008 Rev.

PDF- 145KB DWG- 199KB
2370 Vertical Realignment Of Water Mains PDF- 69KB DWG- 47KB
2372 Minimum Utility Separation Requirements PDF- 70KB DWG- 16KB
2380

Temporary Water Supply Hydrant Meter Assembly

PDF- 118KB DWG- 83KB
2381

Temporary Blow-Off For Water Supply

PDF- 114KB DWG- 83KB
2382

Temporary Water Service

PDF- 107KB DWG- 79KB
2383 Water Line Flushing Assembly 2008 Rev. PDF- 107KB DWG- 79KB
2397 Electronic Ballmarker Placement PDF- 94KB DWG- 199KB
2398 Antenna Mast Detail PDF- 107KB DWG- 87KB
2399 Temporary Tap For Chlorine Injection PDF- 107KB DWG- 87KB